Sensors, probes and analyzers for measuring water parameters
Aqualabo is a French manufacturer recognized worldwide for the quality of its products and instrumentation to perform a wide range of chemical analyses: Reasol stands as the official sales representative for Italy, offering its customers several sensors, analyzers and equipment for monitoring and treatment of industrial water. The products are specially designed to assist the operator in a professional setting in measuring different parameters such as oxygen, conductivity, salinity and pH of water.
We invite you to keep reading in order to find out more information about the products available; alternatively, you can request a personalized consultation with our experts who will be pleased to assist you.
Contact us now via the form or by phone; you can also send us an e-mail.
OPTOD SENSOR, OXIMETER
The OPTOD sensor employs luminescent optical technology and is approved by the international ASTM D888-05 method. With no calibration requirements and using ultra-low power technology, the OPTOD sensor meets the needs of field activities and short- or long-term campaigns. Without oxygen consumption, this technology allows accurate measurement in any situation and especially in very low oxygen concentrations.
APPLICATIONS:
- Control in urban wastewater treatment
- Control in industrial wastewater treatment
- Marine water
- Drinking water
PHEHT SENSOR FOR pH, ORP (Redox) and Temperature (°C)
The PHEHT sensor is designed to adapt to difficult conditions from pure mountain water with conductivity as low as 20 μS/cm, lakes and rivers (100 – 2000 μS/cm), to seawater with conductivity of 50 mS/cm to wastewater with conductivity above 200 mS/cm. This sensor shows a “durable” reference. Plastogel® PONSEL technology increases the duration of the probe by eliminating the need for recharging. This sensor is also designed for portable and on-location applications, which are the most challenging situations for a pH/ORP sensor in terms of sensor durability, fast time responses, minimal flow dependence, and low power consumption.
APPLICATIONS
- Control in urban wastewater treatment
- Control in industrial wastewater treatment
- Monitoring of superficial water
- Marine water
- Drinking water
TECHNICAL SPECIFICATIONS
Sensor:
- Measuring range:
- pH: da 0 to 14 // resolution 0,01 // accuracy ±0,1
- Redox: da – 1000 a + 1000 mV // resolution 0,1 mV // accuracy ±2 mV
- T ° C: da -10 ° C a + 50 ° C // resolution 0,01 °C // accuracy ±0,5 °C
- Working temperature: da 0 ° C a + 50 ° C
- Dimensions:
- diameter 27-21 mm
- length 207 mm
- weight: 350 g
- protection: IP68
- Cable length:
- 3 meters
- 7 meters
- 15 meters
STACSENSE Probe – UV 254 nm
Principle of measurement: the StacSense probe uses UV absorption at 254 nm to measure dissolved organic compounds in water, and the absorbance is correlated with the concentration of TOC, COD and BOD. A reference measurement at 530 nm is used to compensate the presence of particles in the sample that also absorb UV light and to establish the Turbidity parameter. The use of an innovative high-performance UV LED, combined with strict power management, provides optimal signal variation.
APPLICATIONS
- Control in urban wastewater treatment: detection of organic load variations during the input/treatment process/output
- Control in industrial effluents treatment
- Monitoring of superficial water
- Pisciculture, aquaculture (fresh water)
- Drinking water: monitoring organic matter in raw water, oxidation process, coagulation, activated carbon filtration
C4E SENSOR FOR CONDUCTIVITY AND SALINITY
The C4E sensor features a 4-electrodes technology: alternating current of constant voltage is established between a pair of primary graphite electrodes. Platinum secondary electrodes allow to adjust the voltage imposed on the primary electrodes so as to prevent foiling. The voltage measured between the primary electrodes is in the capacity of site resistance and, this, to conductivity.
The C4E sensor stores calibration data and chronology, and this enables a “plug and play” no recalibration system. Thanks to Universal Modbus RS485 protocol, the C4E sensor can be connecter to all commonly used devices (Datalogger, Controller, Automat, Remote System etc).
APPLICATIONS
- Control in urban wastewater treatment
- Control in industrial wastewater treatment
- Monitoring of superficial water
- Marine water
- Drinking water
TECHNICAL SPECIFICATIONS
- Sensor: 4-electrod system (2 graphite, 2 platinum)
- • Conductivity range:
- 0-200,0 μS / cm
- 0 –2000 μS / cm
- 0,00 –20,00 mS / cm
- 0,0 –200, 0 mS / cm
- • Salinity range
- 5-60 g / Kg
- Resolution: da 0,01 a 1
- Accuracy: ± 1%
- Reaction time: <5 seconds
- Working temperature: da 0 ° C a + 50 ° C
- Dimensions:
- diameter 27 mm
- length 157 mm
- weight: 300g
- protection: IP68
- Cable length:
- 3 meters
- 7 meters
- 15 meters
Odeon
ODEON is a hand-held multiparameter device.
True combination of sturdiness and digital intelligence, ODEON offers never-seen-before reliability and flexibility.
With DIGIDENS digital sensors it can measure up to 7 physicochemical parameters.
ODEON is available in the version:
- OPEN ONE (with 1 input for one sensor)
- OPEN X (with 2 inputs for two sensors)
Instrument features:
- Wide 4″ backlit graphic display
- Outstanding memory capacity of 8 MB (up to 100,000 measurements)
- Ergonomic, shock-resistant and waterproof device (IP67)
- Automatic recognition and «Plug and Play» self-diagnostic probes
- Optical sensors (oxygen, turbidity)
- Electrochemical sensors (pH, ORP, temperature, conductivity)
AQUA CONNECT: analyzer for continuous and remote (via Wi-Fi) water monitoring
Real-time data monitoring has never been this easy!
• Local and independent radio communication network
• Secure data transfer and hosting
• No IT management
• Internet browser only for functioning
• Real-time visualization
• At least 2 years of autonomy
• SMS and/or e-mail notifications
Aqua Connect allows real-time tracking of measurements collected by the digital sensors for the following parameters:
- Oxygen
- pH and temperature
- Conductivity
- Salinity
- Redox
- Turbidity
Each sensor is connected to an autonomous wireless “AquaMod” module that records the data collected by the digital sensor. The measurements are transmitted into an “AquaGat” gateway, via LoRaWan independent local network. The collected data is then sent to a secure Cloud server that allows measurements visualization and the transfer in CSV format. Application accessible via any type of browser (Chrome, Firefox, etc.).
ACTEON 5000: fixed analyzer with online digital transmitter
Unlike other analyzers, this instrument allows up to 4 different sensors to be connected in order to perform several analyses at the same time.
ACTEON 5000 allows real-time tracking of measurements collected by the digital sensors for the following parameters:
- Oxygen
- pH and temperature
- Conductivity
- Salinity
- Redox
- Turbidity